Timer Relay Timer 12v Load 120vac Time Control
Timer with 4 configuration options, controls relay ignition counts from 1 second to 999 minutes
Brief introduction of functions:
P-1. The signal activates the relay to activate. When the time is up, the relay is disconnected. During the configured period
Mode A: When activated, a new signal is ignored
Mode B: Time can be reset when new signal is detected
Mode C: The relay is switched and the time is reset when a new signal is detected
P-2. The activation signal starts the timing time T1, when the time is up, the relay disconnects and maintains for the time T2 (reset)
The time of T1 and T2 are adjustable.
P-3. Cyclic use: Does not require activation signal. Turn on the relay for a time T1, turn off for a time T2, endless loop. Both T1 and T2 times are adjustable.
4. When there is a signal, the relay closes and stays closed. When the signal disappears, time begins. When the time is up, the relay turns off. If the signal reappears during the period of time, the action is canceled, and when the signal disappears, the time is restarted.
Description:
1. New version to simplify and meet customer needs.
2. Allows you to protect a power supply with delayed start-up time.
3. Input with photoelectric isolation to improve consumption anti-interference ability.
4. Configuration of the parameters in non-volatile memory. They are not lost after turning off the power supply.
5. The signal terminal voltage signal can be maintained for a long time.
6. Industrial grade plastic case, PLC grade.
* Product parameters:
1. Size: 64.2mm * 34.8mm * 18.5mm
2. Relay specifications: AC 220V 10A or DC 30V 10A.
3. Quiescent current: 20 mA, working current: 50 mA.
4. Operating voltage: 12V (10 to 16V) or 24V
5. Trigger signal: high level voltage 4V to 20V
6. Life: about 100,000 times, working temperature: -40 to 85 ° C
-------------------------------------------------- -------------------------------------------------- ---
Selection of the working mode:
After power on, long press K1, after 2 seconds, enter the selection function mode, P1-1 to P1-4 can be selected.
-------------------------------------------------- -------------------------------------------------- ---
Operating mode
P-1: The signal activates the closing of the relay. When the time is up, the relay is disconnected. The user can set the time T for the relay to close.
Press K2 and the hundreds digit will begin to flash. Press K3 and the hundreds digit will change. ; Press K2 ten-digit number tube to start flashing, press K3 at this time, the ten-digit number changes; press K2 the one-digit number tube to start flashing, press K3 at this time, the ones digit changes; press K2 again; digital Tube no longer flashes, press K3 at this time, decimal point changes, decimal point in ones place means 0 to 999 minutes, tens place means 0 to 99.9 seconds, no decimal point means 0 to 999 seconds; After making the selection, the time setting is now complete. Short press K1 to enter function fine tuning setting. The default delay period is invalid. Press K1 to activate the trigger during the delay period (reprogramming). Press K1 to reset during the delay period (off, relay reset). Press again to repeat the default settings for the first time.
----------------------------------------------- --- ----------------------------------------------- ---
P-2 work mode: The signal is triggered and starts timing X time when the relay is closed and Y is disconnected. The user can configure the X and Y time of the relay activation; the time setting is similar to P1-1, except the blue light is on to set the relay activation time and the blue light is off to set the relay deactivation time. Short press K1 to enter function fine tuning setting. The trigger is invalid during the default delay period. Press K1 to activate the trigger during the delay period (reprogramming). Press again to repeat the first preset.
-------------------------------------------------- -------------------------------------------------- ---
P-3 working mode: turn on for X seconds, turn off for Y seconds, endless loop. The user can set the X and Y time for the relay to close; the time setting is similar to P-2. Short press K1 to enter the fine tuning setting of the function. First turn on X, turn off Y seconds, press K1, turn off X first, turn on Y seconds, and press again to repeat the first default setting.
-------------------------------------------------- -------------------------------------------------- ---
P-4 work mode: The signal causes the relay to close but does not start timing. The activation signal disappears and starts timing T. When the time is up, the relay is disconnected; During the delay period, the signal resumes, the delay is canceled, the pull-in is maintained, and the signal disappears. Restart time; (equivalent to start time when button is released, often used for off delay). The user can set the time T for the relay to close; the time setting is similar to P-1.