Package that includes liter counter with 4 alarms + selector + flow sensor + valve for 2 inch pipe (DN50)+ 12V/3A power supply + USB-Serial cable for monitoring + Ask for Coupon to download JDH FlowVisor for free!
Your data stays safe. We only use it for order fulfillment and won't share to third parties.
Package that includes liter counter with 4 alarms + selector + flow sensor + valve for 2 inch pipe (DN50) + 12V/3A power supply + USB-Serial cable for monitoring + Coupon to download JDH FlowVisor for free.
**Does not include extra wiring, connectors, buttons, or other accessories, only what appears in the images -- THANK YOU!**
With this package you can automate the filling of jugs, buckets, containers, barrels, tanks, bottles or any type of liquid container. It has a selector that allows you to fill 4 different capacities.
Includes 12V normally closed solenoid valve for 2 inch (DN50) pipe
The sensor must be placed in line with the pipe carrying the fluid in a vertical position
The important thing is that during installation the pipe is full at all times, with the liquid completely covering the cross-sectional area of the sensor. For this reason, it is preferred that the sensor be installed in a vertical section of pipe, with the flow running from bottom to top. Otherwise, there is a risk that the turbine will rotate even with any trickle of water running, giving incorrect measurements.
SETTINGS for Sensor: 83333uL/pulse
The Totalizer has a digital input to reset alarms, especially for automation applications for filling tanks/containers or dispensing liquids.
Allows you to configure four alarms that activate an audible alert and a dry contact.
Alarms are activated either by Flow or Volume. If it is by volume, a countdown is kept that decreases by the liters supplied.
Values can be displayed in Liters or Gallons (US)
**Friendly and intuitive touch user interface. The display is multilingual, English, Spanish, French, German and Chinese.
**EASY TO USE
Allows configuration of values by adjusting by decade, for greater speed and convenience.
**Compact and convenient design
Dimensions: 14.5cm*9.0cm*4.1cm
It has screw terminals for connection of the sensor and alarms
Special housing for 35mm DIN rail
**Technical Characteristics and Adjustments
+Power: 6 to 9VDC at 300mA (minimum)
+Ambient temperature: -10°C to 50°C (do not use outdoors, do not expose to solar radiation)
+Minimum measurement: 0.01 Liters
+Maximum measurement: 9,999,999.99 Liters
+Minimum volume alarm countdown: 0.1 Liters
+Maximum volume alarm countdown: 9,999,999.9 Liters
+Liters per pulse minimum: 140ml/pulse
+Liters per maximum pulse: 83400ml/pulse
+Minimum flow measurement of 0.01 L/min
+Maximum flow measurement up to 4960L/min (theoretical with sensor 83400 uL/pulse up to 1000 Hz)
**Dry Alarm Contacts
+Maximum load
+Resistive: 0.40 A at 125 VAC, 2 A at 30 VDC
+Inductive (power factor = 0.4) (L/R = 7 ms): 0.20 A at 125 VAC, 1 A at 30 VDC
+Maximum charging current: 3A
+Maximum operating voltage: 250 VAC, 220VDC
+Maximum switching capacity:
+Resistive: 50VA, 60W
+Inductive (power factor = 0.4) (L/R = 7 ms): 25VA, 30W